Northern Lights offers a full line of optional equipment to make your at-sea power systems as unique as your vessel. Customize your Northern Lights generator set with the quality of our factory-built options and accessories.

  • Exhaust Treatment for Marine Diesel Equipment

Download Brochure

  • Catch tank, alarm and leaking line indicator as required by Lloyd’s, ABS DNV, Germanischer Lloyd’s and other class societies

Request More Information

  • Connects the exhaust system to the engine and reduces vibration transmission through the dry exhaust
  • Allows for remote mounting of the muffler
  • Compensates for the thermal expansion of the exhaust system

Request More Information

  • Adds design flexibility by allowing the fuel tank and generator to be installed further apart
  • Allows easier fuel system bleeding

Request More Information

  • Allows you to view the operational condition of your set
  • Monitor all major engine functions and diagnostics on a read out screen mounted in a convenient locations

Download PV-380 Manual

Download PV-101 Manual

  • Separates the exhaust gas and water mixture allowing the water to exit under the hull and gasses at the transom without the noisy splashing
  • Reduces the exhaust noise so your time aboard is quieter and more enjoyable

Request More Information

  • Increase your battery charging capabilities with a high output alternator
  • Adjustable voltage regulator for use with either lead acid or gell cell batteries is optional
  • Available on M753W2 (6 to 8 kW) and larger models

Request More Information

  • Dramatically reduces noise by placing the muffler and gas/water separator inside the sound enclosure
  • Eases installation and saves engine room space

Download Brochure

  • Make simple repairs and routine maintenance quickly and with confidence
  • Operator’s manuals include photographs and easy-to-read directions
  • Parts manuals offer exploded-view pictures of components and parts numbers
  • Paper manuals come standard; CDs available on request

Open Technical Information Page to download manuals

S-1 Panel

  • The Northern Lights S-1 Panel Includes: Run light, start/stop and shutdown bypass/preheat switch

S1-B Panel

  • The Northern Lights S-1B Panel Includes: Run light, engine hour meter, start/stop, and shutdown bypass/preheat switch

S3-A Panel

  • The Northern Lights S-1B Panel Includes: Run light, engine hour meter, start/stop, and shutdown bypass/preheat switch

Download Specifications

S3-B Panel

  • The Northern Lights S-3B Panel Includes: DC voltmeter, water temperature gauge, oil pressure gauge, engine hour meter, start/stop, and shutdown bypass/preheat switch
  • Includes a NEMA enclosure

Download Specifications

S3-C Panel

  • The Northern Lights S-3C Panel Includes: DC voltmeter, water temperature gauge, oil pressure gauge, engine hourmeter, start/stop, and shutdown bypass/preheat switch
  • Available with enclosure

Download Specifications

S-4 Panel

  • The Northern Lights S-4 Panel includes: Engine temperature gauge, oil pressure gauge, DC and AC voltmeters, AC frequency meter, AC ammeter and switch with harness, start/stop switch, shutdown bypass/preheat switch
  • Available as flush mount or with enclosure

Powerview Panel

Download Specifications

InteliVision 5 CAN Controller Color Display Unit


InteliGen High-End Marine Certified Gen-Set Controller


Request More Information

  • PMG supplies uncorrupted power to the automatic voltage regulator
  • PMG enhances generator performance by making it more tolerant of nonlinear loads and it provides the 300% short circuit capability necessary for Lloyd’s, ABS, DNV, USCG and Germanischer Lloyd’s classifications
  • PMG is standard equipment on M1064A and M1064H and optional on other M1064s

Request More Information

  • Thoughtfully mounted fuel filter is easily serviced
  • Designed to reduce fuel spills
  • Large top mounted air bleed and fuel pump priming lever provide for fast, painless fuel filter changes

Request More Information

  • Optional front power take off with electric clutch
  • Up to 190 HP to run hydraulic equipment

Request More Information

  • Shutdowns for all systems are available
  • Pre-alarms warn you before a shut down occurs

Request More Information

  • Check the oil level in your sump at one quick glance even when the set is running
  • Alarm warns you when oil level is low

Request More Information

  • Prevents raw water from siphoning back into the engine
  • Intended for use with wet exhaust systems only

Request More Information

  • Highest performing enclosures in the industry
  • Sound shields are designed and tested to attenuate up to 20 dBA
  • Trigger latch panels open to single-side serviceability
  • Durable and elegant white, powder-coated finish

Download Brochure

  • Cools hot exhaust gasses and silences exhaust noise
  • Standard model is listed, and a variety of other styles and configurations are also available

Request More Information

Available for models:

M1064T1 50 kW @ 50 Hz

Download Specification Sheet

© Northern Lights, Inc. 2018