Specifications + Dimensions

200 kW50 Hz, 1500 RPM
Voltage regulation1.0%
Frequency
droop control
Isochronous 0%
Standard three
phase power factor
-0.8
Optional single
phase power factor
-1.0
Generator full load
temperature rise
(at 50°C ambient)
Inline cylinders/
operating cycle
95°C/50°C
I-6 / 4
AspirationTurbo &
Seawater Aftercooled
Displacement -
cid (liter)
549
(9.0)
Bore/stroke -
inches (mm)
4.6/5
(118/127)
Fuel injection
pump type
and control
Electronic
(HPCR)
Oil fill capacity -
gal (ltr)
8.3
(31)
(Heat Exchanger Standard)
Heat rejection to
jacket water -
BTU min
13,302
Standard
cooling type
Heat exchange
Freshwater pump
capacity -
gpm (lpm)
64
(243)
HE heat exchanger
approx. coolant
capacity - gal (ltr)
10
(38)
HE seawater pump
capacity -
gpm(lpm)
79
(295)
HE max seawater
pump suction head
lift - ft (m)
9.8
(3)
HE sea water
pump inlet
hose ID - in (mm)
2.5
(63.5)
HE min. seawater inlet/discharge
thru-hull - in (mm)
2.5
(63.5)
DC starting
voltage -
standard
24
Min battery
capacity - amp
750
Starter rolling
amps @ 0°C
300
12 Volt Battery
cable size up
to 10 ft (3m)
2/0
(Based on standard three phase)
Air consumption -
cfm (m3/m)
522
(14.8)
Approx heat
radiated to air -
BTU/min
1619
Generator cooling
air flow 1&3Ø -
cfm
730
Exhaust gas
volume -
cfm (m3/m)
1285
(36.4)
Exhaust gas temp -
F° (C°)
891
(477)
Max. exhaust
back Pressure -
inch H2O
(mm H2O)
30
(762)
Wet and exhaust
elbow OD-
in (mm)
4
(102)
Dry exhaust
elbow OD-
in (mm)
6
(152)
Fuel injection pump
type and control
HPCR
Min suction -
in (mm)
3/8
(10)
Max fuel transfer
pump suction lift -
in (mm)
95
(2408)
Max fuel flow to
transfer pump - gph
N/A
Specific fuel
consumption max load
- lbs.hp.hr
0.357
Approx. fuel rate @ (100%) full load- gph (lph)14.4
(54.5)
Continuous (with separate expansion tank)20o
Intermittent (2 minutes)30o
Length106 in
(2692 mm)
Width42 in
(1067 mm)
Height49.5 in
(1258 mm)
Approximate
weight
5740 lbs
(2604 kg)
Dimensions provided for information only. Do not use for installation. Contact factory for installation drawings and info.

Features + Benefits

Lugger six cylinder, four cycle, in-line, liquid cooled, overhead valve, marine diesels based on heavy-duty industrial engine blocks. .Balanced, forged crankshaft with induction hardened journals and rolled fillets for long life. .Replaceable, wet cylinder liners for long life and low rebuild costs. .Bimetallic valves have chrome stems and rotators…Replaceable valve seats and guides. Three ring aluminum alloy pistons with Ni-Resist insert for the top ring. Keystone piston ring reduces carbon buildup under light loads. Torsional crankshaft dampers help ensure smooth operation. .A single poly-vee drive belt powers the alternator and jacket-water pump.

Heat exchanger cooling: Cupronickel, tube type heat exchanger with removable ends for easy cleaning. Gear driven, beltless, flexible impeller, sea water pump is bronze and stainless steel. Cast expansion tank with brass fi ller neck. Two thermostats for quick warm-ups and safety. Cast-iron exhaust manifold for even temperature control. Heat exchange configuration standard.

High pressure common rail fuel injection for smooth, clean delivery. Direct fuel injection systems. Canister fuel filters include drain and sensors for low fuel pressure and water-in-fuel. Electric Fuel transfer pump with automatic priming.

Dry air fi lter silences intake noise. Turbocharger with jacket water cooled turbine housings for safety. Sea water aftercooler provides optimized combustion and output.

.Positive displacement gear-type oil pump. Full fl ow, spin-on oil fi lter. .Oil spray cooling reduces piston crown temperature for longer life. .Jacket-water, plate-type, full fl ow oil cooler reduces heat and prevents lube oil breakdown. Large capacity oil pan. A closed loop crankcase vent traps oil vapor to keep the engine room clean.

Electronic System Profiler (ESP) supplies an SAE J1939 data stream through a CANbus plug. Optional engine monitor screen. .Negative ground, 24 volt DC system has circuit breaker, starter motor and alternator with regulator. Generator mounted start/stop switches are standard. Optional S-3C remote control panel with engine hour meter, coolant temperature gauge, oil pressure gauge, DC voltage meter, start-stop and shutdown bypass switches. Additional optional panels help you specify the amount and type of information delivered. Reliable, relay based DC system is easy to trouble shoot and repair. Up to 6 panels can be used up to 110 feet from set. Low oil pressure and high coolant temperature safety shutdown system.

Direct coupled, single bearing, 12 lead, re-connectable AC generator. Maintenance free brushless design. All NL generators meet or exceed class society standards with Class “H” insulation, accessible diodes, oversized ball bearings, marine grade shafts and heat rise rating.* Engines and generators are torsionally matched for long life. Automatic voltage regulator; ±1.5% regulation over the entire range from no load to full load. Configured for isochronous frequency control with ECU electronic governor control. * less than 95°C/50°C

© Northern Lights, Inc. 2018