Specifications + Dimensions

50 Hz / 1500 rpm: 85 kW
100 kW
108 kW
117 kW
Voltage Regulation:+/- 0.5%
Frequency Droop Control:Isochronous 0%
Phase and Power Factor:Three phase -
0.8 power factor std.
Generator Full Load Temperature Rise:125°C temperature rise
at 40°C ambient

[table id = 842 /}

(Keel Cooling standard)
Heat Rejection to Jacket Water -1500 rpm BTU min:
C4105A1
C4105A2
C4105A3
C4105A4

2343
2908
3090
C/F
Freshwater Pump Capacity - gpm (lpm):50 (190)
Engine Only Approximate Capacity - gal (ltr):9.7 (37)
Heat Exchanger Approx. Cooling Capacity - gal (ltr):8.2 (31)
Raw Water Pump Capacity - gpm (lpm):40 (151)
Max. Raw Water Pump Suction Head Lift - in (mm):39 (1000)
Raw Water Pump Inlet Hose ID - in (mm):2 (51)
Min. Raw Water Inlet/Discharge Thru-Hull - in (mm):2 (51)
(12V standard, 24V optional)
DC Starting Voltage - Standard (Optional):12 (24)
Min. Battery Capacity - amp hr:90
Min. Battery Size - CCA:750
Starter Rolling Amps at 0°C - 12V (24V):420 (225)
12 Volt Battery Cable Size Up to 5ft (1.5m) - mm²:50
Air Consumption - m³/m (cfm):
C4105A1
C4105A2
C4105A3
C4105A4

4.1 (146)
4.4 (157)
4.6 (162)
4.8 (169.8)
Approx. Heat Radiated to Air; Engine & Generator - BTU/min:
C4105A1
C4105A2
C4105A3
C4105A4

1304
1529
1655
1799
Generator Cooling Air Flow 1&3Ø - m³/m (cfm):
C4105A1-3
C4105A4

72 (2542)
84 (2966)
Exhaust Gas Volume - kg/hr (lbs/min):
C4105A1
C4105A2
C4105A3
C4105A4

431 (15.8)
473 (17.4)
507 (18.6)
540 (19.8)
Exhaust Gas Temp. - C° (F°):
C4105A1
C4105A2
C4105A3
C4105A4

462° (864°)
482° (899°)
499° (930.2°)
524° (975.2°)
Max. Exhaust Back Pressure - in H²O (mm H²O):30 (762)
Wet Exhaust Elbow OD- in (mm):5 (127)
Dry Exhaust Elbow - in (mm):4 (102)

See Specification Sheet for more details

See Specification Sheet for more details

See Specification Sheet for more details

Features + Benefits

See Specification Sheet for more details

See Specification Sheet for more details

  • Positive displacement gear-type oil pump.
  • Full flow, spin-on oil filter.
  • Oil spray cooling reduces piston crown temperature.
  • Jacket-water, plate-type, full flow oil cooler reduces heat and prevents lube oil breakdown.
  • Large capacity oil pan.
  • A closed loop crankcase vent traps oil vapor to keep the engine room clean.

See Specification Sheet for more details

See Specification Sheet for more details

See Specification Sheet for more details

See Specification Sheet for more details

See Specification Sheet for more details

Note:

  1. Prime kW ratings for 3Ø at 0.8 power factor. Consult factory for deration factors.
  2. Based on prime kW rating at 1800 and 1500 RPM. Fuel rate may vary depending on operating conditions.

Dimensions are subject to change without notice, they are not intended for installations.

Contact a factory representative for the current installation data.

© Northern Lights, Inc. 2018